Overview

MAXPOWER Series is a small to medium power transformer-less UPS of CellNor. This series is the classic product of CellNor. It
releases very early and designs with high standard; This series is improved continually combined with customers’
application feedback, and it became a very cost-effective product series. This product series has a very good sale
performance , and received highly praises from customers. The categories of this UPS are abundant, and the product is
stable and reliable, it can meet the demands of small to medium power UPS of customers.

Specification

GENERAL FEATURES

  • High power density.

  • Output power factor up to 0.9.

  • Three stage charging mode extends battery life,

  • optimizes recharging time.Selectable high efficiency mode of operation.

  • Cold start.

  • Standard communication options: RS232
    communication port, USB communication port,
    and relay output contacts or SNMP card.

  • Power shedding function may turn off uncritical
    load in battery backup to make longer backup
    time for critical load.

  • Extended runtime with up to four extended
    battery modules (EBPs) per UPS.

  • Emergency shutdown control through the remote
    emergency power-off (EPO) port.

  • Versatile LCD human-computer interface.

Model CN7001MPI/CN7001MPE CN7002MPI/CN7002MPE CN7003MPI/CN7003MPE

Capacity

VA

1000

2000

3000

Watts

900

1800

2700

Phase

Single phase with ground

Input

Normal Voltage

200/208/220/230/240Vac or 100/110/115/120/127Vac

Input Voltage Range

110~300Vac or 55~150Vac @ 60% load,160~300Vac or 80~145Vac @ 100% load

Frequency Range

45~55Hz/55~65Hz (Auto-detect)

Power Factor

≥0.99 @Nominal voltage(100% load)

Output

Output Voltage

200/208/220/230/240Vac or 100/110/115/120/127Vac

Power Factor

0.9

Voltage Regulation

±1%

Frequency

Line mode
(Synchronized range)

45~55Hz / 56~64Hz

Bat. mode

50Hz / 60Hz ±0.1Hz

Crest Factor

3:1

Harmonic Distortion (THDv)

≤3% THD(Linear load)

≤6% THD(Non-linear load)

Transfer time

AC to DC

Zero

Inverter to bypass

4ms(Typical)

Waveform

Pure sinewave

Efficiency

AC Mode

88%

89%

90%

Battery Mode

83%

85%

86%

Battery

Standard
Model

Battery Type

12V/9AH

Numbers

2/3

4/6/8

6/8

Backup time

Estimated remaining time displayed on the LCD

Typical Recharging Time

4 hours recover to 90% capacity

Charging current(max.)

1.0A

Charging Voltage

27.4/41.1Vdc ±1%

54.7Vdc /82.1Vdc /109.4Vdc±1%

82.1Vdc /109.4Vdc ±1%

Long-run
Model

Battery numbers

Depending on the capacity of external batteries

Charging current(max.)

6A/12A(Double board)

Charging Voltage

27.4/41.1Vdc ±1%

54.7Vdc/82.1Vdc/109.4Vdc±1%

82.1Vdc/109.4Vdc ±1%

Indicators

LCD 

Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators

Alarm

Battery Mode

Beeps every 4 seconds

Battery Low

Beeps every second

Overload

Beeps twice per second

Fault

Continously beeping

Environment

Humidity

20-90% RH @ 0-40°C (Non-condensing)

Noise Level

<50dB @ 1 Meter

Physical

Dimension

Standard model

400×144×215

470×191×336

Long run model

400×144×215

470×191×336

Weight

Standard model

10/13

17.8

20.1/25.1

Long run model

5.6

11.0

11.5

Management

Smart RS232/USB

Supports Windows® 2000/2003/XP/Vista/2008 Windows® 7/8 Linux, FreeBSD and MAC

Optional SNMP

Power management from SNMP manager and web browser

Specifications are subject to change without prior notice

Model CNBC101M CNBC102M CNBC103M CNBC104M CNBC105M

Capacity

VA

24

36

48

72

96

Watts

9

9

9

9

9

Input

Voltage

150~285Vac or 80~145Vac

Phase

Single phase with ground

Output

Output Voltage

(27.4±1)Vdc

(41.1±1)Vdc

(54.8±1)Vdc

(82.2±1)Vdc

(110±1)Vdc

Charging mode

CV mode

Charging current(Max)

1.4A

Leakage current

<100uA

Phase

Single phase with battery ground

Battery

Number of batteries per set 

2

3

4

6 8

Number of batteries set

2

Battery type

12V/9Ah

Backup time

In accordance with the battery capacity and load

Typical recharging time

In accordance with the battery capacity

Rated battery voltage

24VDC

36VDC

48VDC

72VDC

96VDC

Battery current protection

60A fast fuse

Environment

Safety

CE

Operating environment

0~40°C

Relative humidity

0~90% (Non-condensing)

Noise level

<40dB@ 1Meter

I/O Socket

Battery socket

Anderson like power pole modular connec tors

Physical

Dimension

400×144×215

470×191×336

Net weight

17.5

19

25.5

35.5

45.5

 

STANDARDS      

 

Input socket

IEC320 C13-10A

AC power cord

IEC320 C14-10A

                                                                      

Ordering Information

Part Number Description

CN7001MPI

1kVA Medium Power Transformerless UPS (Internal battery) Rack Mount

CN7001MPE

1kVA Medium Power Transformerless UPS (External battery) Rack Mount

CN7002MPI

2kVA Medium Power Transformerless UPS (Internal battery)

CN7002MPE

2kVA Medium Power Transformerless UPS (External battery)

CN7003MPI

3kVA Medium Power Transformerless UPS (Internal battery)

CN7003MPE

3kVA Medium Power Transformerless UPS (External battery)

CNBC101M

24 VDC Battery Pack

CNBC102M

36 VDC Battery Pack

CNBC103M

48 VDC Battery Pack

CNBC104M

72 VDC Battery Pack

CNBC105M

96 VDC Battery Pack

Downloads

Downloads For Partners

DataSheet PDF 171.08KB DOWNLOAD

INTERESTED IN OUR PRODUCT RANGE?